Description
The model 4300SA series provides a load circuit with operating voltage for a predetermined
amount of time each time the operating voltage is applied. The operating voltage must be
present for the duration that exceeds the preset timing period. The 4300SA series is
available in both AC and DC models and controls output load circuits to 1 ampere.
The DIP switch is used to set the desired delay, 3 ranges cover 0.1-102.4
seconds, 1-1024 seconds (std), and 2-2048 seconds.
Specifications
| Operating Voltage |
5, 12, 24, 48V DC or 12, 24, 48, 115, 230V AC, 50/60Hz. |
| Output |
10 milliamperes to 1 Amperes inductive with Inrush current
to 25 amperes for 8 milliseconds. |
| Timing Mode |
Interval |
| Timing Range |
1-1024 seconds, 0.1-102.4 seconds (-1),
2-2048 seconds (-2) |
| Repeatability of Timing Period |
+/- 1% nominal. |
| Recycle Time |
200 milliseconds minimum |
4300SA Specifications
: click to view , right click -
Save As ... to download.
Ordering Information
| Model |
Voltage |
Time Delay Dash Number |
| 4300SA |
-1 5VDC -5
12VAC
-2 12VDC -6 24VAC
-3 24VDC -7 48VAC
-4 48VDC -8 115VAC
-9 230VAC |
None = 1-1024 seconds
-1 = 0.1-102.4 seconds
-2 = 2-2048 seconds |
Examples:
4300SA-6 operates from 24VAC with time delays from 1-1024 seconds.
4300SA-2-2 operates from 12V DC with time delays from 2-2048 seconds |