| Operating Voltage |
24 VDC ±20%. 2A circuit breaker on power input |
| Dispense Timing |
From 2.0 seconds to 14.0 seconds in 0.5 sec increments. |
| Dispense Axle Counts |
From 1 to 128 axle counts. |
| Maximum Axle Counts |
LED display can show up to 99,999,999 counts. |
| Maximum Dispense Volume |
LED display can show up to 9,999,999.9 cu. in. |
| Recycle Time |
Operating voltage must be removed for a minimum of 200 milliseconds to
guarantee system have reset. |
| Relay Output Rating |
Automotive bracket mounted relay, NO contacts rated for 40A . Connected to
terminal blocks and 15A breaker with 14 AWG wires and ¼" QD lugs. |
| Piston Detect - RainSnow Inputs |
On/Off inputs can accomodate normally open contacts or solid state outputs.
Solid state outputs must provide less than 1mA leakage current @ 24VDC
when off and must reliabily switch a 10mA resistive load. |
| Terminal Block |
Terminals blocks mounted on interior panel for wiring. 8mm euro-style blocks
rated for 20A @ 300V, 12-22 AWG wires. |
| Transient Protection |
On all inputs. |
| Digital Display |
500V rms all terminals to case. |
| Operating Temperature |
-40°C to +85°C. |
| Humidity |
95% non-condensing. |
| Construction |
PCB conformally coated. Fiberglass polyester case is NEMA 1, 2, 3, 4, 4X, 12
& 13 rated before installation of wiring openings. |